PURE M3700 Instalační manuál

Procházejte online nebo si stáhněte Instalační manuál pro Brány / ovladače PURE M3700. PURE M3700 Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 128
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Model No.
KX-TDE600
Pure IP-PBX
Installation Manual
SD Logo is
a trademark.
Document Version: 2009-12
Thank you for purchasing a Panasonic Pure IP-PBX.
Please read this manual carefully before using this product and save this manual for future use.
KX-TDE600: PGMPR Software File Version 3.0000 or later
Zobrazit stránku 0
1 2 3 4 5 6 ... 127 128

Shrnutí obsahu

Strany 1

Model No. KX-TDE600Pure IP-PBXInstallation ManualSD Logo isa trademark.Document Version: 2009-12Thank you for purchasing a Panasonic Pure IP-PBX.Pl

Strany 2

1. Information stored on the SD Memory CardPhonebook data, user IDs, system settings data, passwords (User/Administrator/Installer), PersonalIdentific

Strany 3

2. Check that the shelves are standing exactly vertically. If the shelves are leaning slightly to one side, movethe base stands to adjust the position

Strany 4

Installing Expansion Shelves 2 and 3Repeat the procedure in "Installing the Basic Shelf and Expansion Shelf 1" for Expansion Shelves 2 and 3

Strany 5

Connecting ShelvesFor the 4-shelf system, you need to install an optional BUS-M card and BUS-ME cards in the Basic Shelf. Toconnect the shelves, plug

Strany 6

3. Push the release lever in the direction of the arrow so that the BUS-M card engages securely with theconnector on the back board.Release LeverBack

Strany 7

5. Plug each Bus Cable into the corresponding port of the BUS-M card in the Basic Shelf. Then, plug theother end into the BUS-S card in each Expansion

Strany 8

6. Attach the noise shield wires of each Bus Cable to the Basic Shelf and each Expansion Shelf with thescrews of the BUS-M card.NoteWhen attaching or

Strany 9

3.2.8 Wall Mounting (KX-TDE600/KX-TDE620)Mounting ShelvesWARNING• Make sure that the wall that the shelf will be attached to is strong enough to supp

Strany 10

1. Install 4 anchor plugs in the wall, using the metal bracket as a template. Fix the metal bracket with 4 screws(A).30 mm(1-3/16 in)8 mm(5/16 in)Anch

Strany 11

2. Hook the shelf onto the metal bracket, making sure that the shelf slides down and onto the hooked partsof the metal bracket. Use 2 screws (B) to fi

Strany 12

3.2.9 Installing/Replacing the Power Supply UnitFunctionPSU Type Lower/Upper Input Voltage Range Current Input FrequencyPSU-MLower: 100 V AC to 130 V

Strany 13

PrecautionWARNINGDO NOT REMOVESD MEMORY CARDWHILE POWER ISSUPPLIED TO THE PBXDoing so may cause the PBX to fail to start when you try to restart the s

Strany 14

The following procedures are for installing or replacing a PSU only. Do not replace or remove the PSUfor any other purpose.Installing the Power Supply

Strany 15

3. Turn the 4 screws clockwise, in the order indicated by the numbers 1 to 4, to fix the PSU.1324ScrewsReplacing the Power Supply Unit1. Unplug the AC

Strany 16

3. Pull the release lever in the direction of the arrow to disconnect the PSU from the back board.Release LeverBack Board4. Replace the PSU.Current PS

Strany 17

3.2.10 Frame Ground Connection1. Loosen the screw.2. Insert a grounding wire (user-supplied).3. Tighten the screw.4. Connect the grounding wire to gr

Strany 18

3.2.11 Installing/Removing the Optional Service CardsCAUTION• To protect the back board from static electricity, do not touch parts on the back board

Strany 19

3. Turn the 2 screws clockwise to fix the card in place.ScrewsNoteMake sure the screws are tightened to ground the card securely.Document Version 200

Strany 20

Covering the Blank SlotsBe sure to cover each slot in which no optional service card is installed by using a Blank Slot Cover.CAUTIONFailure to instal

Strany 21

Removing the Optional Service Cards1. Turn the 2 screws counterclockwise to loosen them.Screws2. Pull the release lever in the direction of the arrow

Strany 22

3.2.12 Cable HandlingNoteFor safety reasons, do not stretch, bend, or pinch the AC power cord.Cable Handling for Each ShelfWhen cables are connected

Strany 23

Cable Handling for Connected ShelvesWhen running connected cables towards the back of the shelves, make sure not to block the opening of eachFan Guard

Strany 24

Password SecurityCAUTIONTo the Administrator or Installer regarding the system password1. Please provide all system passwords to the customer.2. To av

Strany 25

3.2.13 Types of ConnectorsConnector Type Pin Number Used forRJ11(Twisted pair cable)14• DHLC8 (KX-TDA0170)• SLC8 (KX-TDA0173)• CSLC16 (KX-TDA0177)• E

Strany 26

Connector Type Pin Number Used forRS-232C(Shielded cable)9 56 1• Basic Shelf (KX-TDE600)Mini Plug24• IPCEMPRDocument Version 2009-12 In

Strany 27

3.2.14 Attaching a Ferrite CoreA ferrite core must be attached when:• an RJ45 connector is connected to IPCEMPR, IP-GW16 or IP-EXT16 cards, or• an Am

Strany 28

Attaching to an Amphenol ConnectorFor Extension CardsPass the cable through the ferrite core, then close the case of the ferrite core. Attach the ferr

Strany 29

3.2.15 Fastening Amphenol ConnectorAn Amphenol 57JE-type connector is used on some of the optional service cards.To connect an Amphenol connector, us

Strany 30

Amphenol Connector Pin Assignment ChartBelow is an Amphenol connector pin assignment chart for all optional service cards that use the Amphenolconnect

Strany 31

3.2.16 Surge Protector InstallationCAUTIONPerforming surge protection is essential. Make sure to follow the instructions in this section.OverviewA ma

Strany 32

Outside Installation(Main Building)CO LineCO LineExtn.Extn.Extn.: Extension LineGroundExtn.Surge ProtectorSurgeProtectorPBXExtn.SLTPTPT-interface CSCS

Strany 33

1. Connect the grounding rod to the surge protector using a grounding wire with a cross-sectional area of atleast 1.3 mm2.2. Bury the grounding rod ne

Strany 35

IntroductionThis Installation Manual is designed to serve as an overall technical reference for the Panasonic Pure IP-PBX,KX-TDE600. It provides instr

Strany 36

F.C.C. REQUIREMENTS AND RELEVANTINFORMATION1. Notification to the Telephone CompanyThis equipment complies with Part 68 of the FCC rules and the requi

Strany 37

interference in a residential installation. This equipment generates, uses, and can radiate radio frequencyenergy and, if not installed and used in ac

Strany 38

Table of Contents1 System Outline ...191.1 System Construction ...

Strany 39

3.7.2 CID8 Card (KX-TDA0193) ...1423.7.3 T1 Card (KX-TDA0187)

Strany 40

6 Appendix ...2216.1 Revision History ...

Strany 41

Section 1System OutlineThis section provides general information on the PBX,including the system capacity and specifications.Document Version 2009-1

Strany 42

System ComponentsSystem Components TableCategory Model No. DescriptionBasic Shelf KX-TDE600 Basic ShelfMain Processing Card Main Processing Card (IPCE

Strany 43

1.1 System Construction1.1.1 Basic SystemBasic ShelfThe Basic Shelf contains an IPCEMPR card for controlling the PBX. To use the basic system, insta

Strany 44

1.1.2 Expanded SystemExpansion ShelfEach Expansion Shelf contains a BUS-S card for connecting to the Basic Shelf. To use Expansion Shelf,connect it t

Strany 45

2-shelf SystemExpanded system (Basic Shelf + 1 Expansion Shelf). Expansion Shelf 1 is mounted on the Basic Shelf.CAUTIONIf you are installing a 2-shel

Strany 46

3-shelf System (Tower Type)Expanded system (Basic Shelf + 2 Expansion Shelves). Expansion Shelves 1 and 2 are mounted on the BasicShelf. A Mounting Ki

Strany 47

4-shelf System (Tower Type)Fully expanded system (Basic Shelf + 3 Expansion Shelves). Expansion Shelves 1 to 3 are mounted on theBasic Shelf. A Mounti

Strany 48

4-shelf System (Side-by-side Type)When vertical space is limited, it is possible to install a fully expanded system (Basic Shelf + Expansion Shelf1, a

Strany 49

1.1.3 System Connection DiagramDoorphone & Door OpenerBGM/Music On Hold (MOH)Pager/SpeakerRemote PCPCPrinterCO (Telephone Company) LinesAnalog/PR

Strany 50

CSIF4(KX-TDA0143)CSIF8(KX-TDA0144)PSU-M/L(KX-TDA0104/KX-TDA0103)EMSLC16(KX-TDA6175)EXT-CID(KX-TDA0168)ESLC16(KX-TDA6174)SLC8(KX-TDA0173)DSP16(KX-TDE01

Strany 51

1.2 Optional Equipment1.2.1 Optional EquipmentModel No. Model Name DescriptionKX-TDE0105 Memory Expansion Card(IPCMEC)Memory expansion card to incre

Strany 52

Model No. Model Name DescriptionKX-TDA0177 16-Port Single Line TelephoneExtension Card with Caller ID(CSLC16)16-port extension card for SLTs with Call

Strany 53

Category Model No. DescriptionKX-NCS4704 4-Channel SIP Extension Activation Key (4 SIP Extension)KX-NCS4708 8-Channel SIP Extension Activation Key (8

Strany 54

Model No. Model Name DescriptionKX-TDA6175 16-Port Single Line TelephoneExtension with Message LampCard (EMSLC16)16-port extension card for SLTs with

Strany 55

1.3 Specifications1.3.1 General DescriptionControl Bus Original bus (16-bit, 8 MHz, 10 megabytes per second)Communication Bus H.100 bus conformity (

Strany 56

PT-interface CS 1-pair wire (D1, D2)PT-interface CS (High-density) 4-pair wire (D1, D2)DSS Console and Add-on KeyModule1-pair wire (D1, D2)Dimension B

Strany 57

1.3.2 CharacteristicsTerminal Equipment Loop Limit• PT: KX-DT300/KX-T7600 series DPT: 90 W; all other DPTs/APTs:40 W• SLT: 600 W including set• Doorp

Strany 58

1.3.3 System CapacityType and Maximum Number of SlotsThe PBX supports the following type and number of slots.Slot TypeMaximum NumberBasic System2-she

Strany 59

Virtual Slots of the IPCEMPR CardIPCEMPR CardVirtual SlotsVirtual CO Line SlotsVirtualExtension SlotsMaximum Optional Service CardsThe following numbe

Strany 60

Cards Installed in Free Slots or Virtual Slots*1 *1*3BasicSystem112214 4044103054010 40V-IPGW16ELCOT16T1PRI23IP-GW4EIP-GW16V-IPEXT32V-IPCS4V-SIPEXT32D

Strany 61

Cards Mounted on Other Optional Service CardsCard TypeMaximum NumberMounted onBasic System2-shelfSystem3-shelfSystem4-shelfSystemDSP161IPCEMPRCardDSP6

Strany 62

Maximum CO Lines and ExtensionsThe PBX supports the following number of CO lines and extensions.TypeBasicSystem2-shelfSystem3-shelfSystem4-shelfSystem

Strany 63

Maximum Terminal EquipmentThe following number of items of terminal equipment can be supported by the PBX.Terminal Equipment Type Basic System2-shelfS

Strany 64

Category Model No. DescriptionKX-TDA0170 8-Port Digital Hybrid Extension Card (DHLC8)KX-TDA0171 8-Port Digital Extension Card (DLC8)KX-TDA0172 16-Port

Strany 65

Note for KX-NT265 IP-PT usersThe supported card varies depending on the software version of your KX-NT265 IP-PT. To confirm the version,follow the pro

Strany 66

PSU CapacityEach PSU supports a different load figure.PSU Type Maximum Load FigurePSU-M 128PSU-L 512If the total load figure is greater than 128, you

Strany 67

42 Installation Manual Document Version 2009-12 1.3.3 System Capacity

Strany 68

Section 2Activation Key InstallationThis section describes information on activation keys,including how to obtain an activation key and install it in

Strany 69

2.1 Information about the Activation Keys2.1.1 Activation KeysTo use IP CO lines and IP telephones on a private IP network using the IPCEMPR card or

Strany 70

Activation Key Type DescriptionMaximumNumberSupported IP CO lines/IP Telephones/CAUsersCA Basic 128usersAllows the use of CA Basic for 128users.1 128

Strany 71

Activation Keys for IP CO LinesModel No. Activation Key TypeMaximum Number/Supported IP CO Lineswith DSP16 with DSP64KX-NCS4102 2 IP Trunk 3060 IP CO

Strany 72

Model No. Activation Key Type Maximum Number Supported CA UsersKX-NCS2205 CA Pro 5users 25 125 usersKX-NCS2210 CA Pro 10users 12 120 usersKX-NCS2240 C

Strany 73

2.1.2 Activation Key Code and Key Management SystemTo obtain additional activation keys, you need to purchase the appropriate activation key codes an

Strany 74

2.1.3 Activation Key FileThe corresponding number of IP CO lines and IP telephones or enhanced features can be activated by installingthe downloaded

Strany 75

Category Model No. DescriptionProprietary Equipment KX-A258 Blank Slot CoverKX-T30865 DoorphoneKX-T7765KX-T7775*1Note that the types of activation key

Strany 76

50 Installation Manual Document Version 2009-12 2.1.3 Activation Key File

Strany 77

Section 3InstallationThis section describes the procedures to install thePBX. Detailed instructions for planning the installationsite, installing the

Strany 78

3.1 Before Installation3.1.1 Before InstallationPlease read the following notes concerning installation and connection before installing the PBX and

Strany 79

• Do not stack up the optional service cards.Wiring PrecautionsBe sure to follow these instructions when wiring the unit:WARNING• Do not run unshielde

Strany 80

3.2 Installation of the PBX3.2.1 UnpackingSupplied Items for the Basic Shelf (KX-TDE600)Unpack the box and check the items below:Main Unit 1Ferrite

Strany 81

Supplied Items for an Expansion Shelf (KX-TDE620)Unpack the box and check the items below:Main Unit 1Metal Bracket 1Anchor Plug 4Fan Guard 2Screw A 4S

Strany 82

3.2.2 Names and LocationsInside ViewBasic Shelf (KX-TDE600) Expansion Shelf (KX-TDE620)ABFCABGEJKHEDIA. RUN IndicatorB. ALARM IndicatorC. MNT PortD.

Strany 83

3.2.3 Opening/Closing the Front CoverOpening the Front Cover1. Insert a flathead screwdriver into the opening (on the left of the screw cover) and un

Strany 84

Closing the Front Cover1. Hook the front cover onto the shelf (line up the protrusions on the cover with the receptacles on the shelf).Then slide the

Strany 85

3.2.4 Attaching Fan GuardsAttaching Fan GuardsFan Guards (supplied with the shelf) must be attached using the screws (C) when:• installing a multiple

Strany 86

• Single line telephonesIncompatible Panasonic Proprietary TelephonesThe PBX does not support the following telephones:• KX-T30800 series proprietary

Strany 87

3.2.5 Installation of Basic System or 2-shelf System (FloorStanding)The PBX can be expanded to a 2-shelf system by mounting an Expansion Shelf on the

Strany 88

Installing the Basic ShelfFor the basic system, install the metal bracket (supplied with the Basic Shelf) on the floor first. Then, attachthe Basic Sh

Strany 89

3. Secure the Basic Shelf to the metal bracket with 2 screws (B).Screw (B)Installation of the basic system is complete. If you are installing a 2-shel

Strany 90

2. Fix the metal bracket to the Basic Shelf with 4 screws (B).TOPScrew (B)Metal Bracket3. Lift Expansion Shelf 1, attach it to the metal bracket on th

Strany 91

4. Secure Expansion Shelf 1 to the metal bracket with 2 screws (B).Screw (B)Shelf installation is complete. Next, it is necessary to connect the shelv

Strany 92

Connecting ShelvesFor the 2-shelf system, you need to install an optional BUS-M card in the Basic Shelf. To connect the shelves,plug the Bus Cable (su

Strany 93

3. Turn the 2 screws clockwise to fix the BUS-M card in place.Screws4. Plug the Bus Cable into the bottom port of the BUS-M card in the Basic Shelf. T

Strany 94

5. Attach the noise shield wires of the Bus Cable to the Basic Shelf and Expansion Shelf 1 with the screwsof the BUS-M card.NoteWhen attaching or remo

Strany 95

3.2.6 Installation of 3- or 4-shelf System (Tower Type)The PBX can be expanded to a 3- or 4-shelf system by mounting Expansion Shelves on the Basic S

Strany 96

WARNINGBe careful not to drop any components. Dropping components may damage them or cause aninjury.CAUTION• Do not block the openings of the shelf. A

Strany 97

Important Safety InstructionsWhen using your telephone equipment, basic safety precautions should always be followed to reduce the riskof fire, electr

Strany 98

NoteIf necessary, it is possible to reverse the direction of the base stands as shown below:2. Place the metal bracket on the base stands.Metal Bracke

Strany 99

3. Attach the metal bracket to the base stands with 4 screws (B).Screw (B)4. Make 4 holes for anchor plugs on the floor, using the measurements indica

Strany 100

5. Install 4 anchor plugs in the holes on the floor.Then, fasten the base stands to the floor loosely with 4 screws (A). (This makes it easy to adjust

Strany 101

7. Lift the Basic Shelf, attach it to the metal bracket, and slide it backwards until it locks.FRONT12FRONT12TOPTOPMetal Bracket8. Secure the Basic Sh

Strany 102

Mounting Expansion Shelves 1 and 2For the 3- or 4-shelf system, attach the metal bracket (supplied with the Expansion Shelf) to the Basic Shelffirst.

Strany 103

3. Lift Expansion Shelf 1, attach it to the metal bracket on the Basic Shelf, and slide it backwards until it locks.12Metal Bracket4. Secure Expansion

Strany 104

Fixing to the Wall1. Attach the metal bracket to the wall brackets.Wall Bracket (Left) Wall Bracket (Right)Metal Bracket2. Fix the metal bracket to Ex

Strany 105

3. Install 4 anchor plugs in the wall, using the wall brackets as a template. Fix the wall brackets to the wallwith 4 screws (A).Notice• Drive mountin

Strany 106

4. Check that the shelves are standing exactly vertically. If the shelves are leaning slightly to one side, movethe base stands to adjust the position

Strany 107

Expansion Shelf 21. Lift Expansion Shelf 2, attach it to the metal bracket fixed on Expansion Shelf 1, and slide it backwardsuntil it locks.12Metal Br

Strany 108

Important InformationSAVE THESE INSTRUCTIONSWARNINGSAFETY REQUIREMENTSFor All Telephone Equipment• Do not install the product in any other way than de

Strany 109

Mounting Expansion Shelf 3For the 4-shelf system, attach the metal bracket (supplied with Expansion Shelf 3) to Expansion Shelf 2 first.Then, attach t

Strany 110

3. Remove the 4 tabs on the top cover of Expansion Shelf 3, by using a flathead screwdriver, as shown below.Expansion Shelf 34. Fasten the wall bracke

Strany 111

5. Lift Expansion Shelf 3, attach it to the metal bracket fixed on Expansion Shelf 2, and slide it backwardsuntil it locks.12Metal Bracket82 Installat

Strany 112

6. Secure Expansion Shelf 3 to the metal bracket with 2 screws (B).Screw (B)Document Version 2009-12 Installation Manual 833.2.6 Installation of 3-

Strany 113

Fixing to the Wall1. Install 4 anchor plugs in the wall, using the wall brackets as a template. Fix the wall brackets to the wallwith 4 screws (A).Not

Strany 114

2. Check that the shelves are standing exactly vertically. If the upper shelves are leaning slightly to one side,move Expansion Shelf 3 to adjust the

Strany 115

Connecting ShelvesFor a 3- or 4-shelf system, you need to install an optional BUS-M card and BUS-ME card(s) in the Basic Shelf.To connect the shelves,

Strany 116

3. Push the release lever in the direction of the arrow so that the BUS-M card engages securely with theconnector on the back board.Release LeverBack

Strany 117

5. Plug each Bus Cable into the corresponding port of the BUS-M card in the Basic Shelf. Then, plug theother end into the BUS-S card in each Expansion

Strany 118

6. Attach the noise shield wires of each Bus Cable to the Basic Shelf and each Expansion Shelf with thescrews of the BUS-M card.NoteWhen attaching or

Strany 119

• Unplug all installed shelves of the system from the AC outlet if it emits smoke, an abnormal smell or makesunusual noise. These conditions can cause

Strany 120

3.2.7 Installation of 4-shelf System (Side-by-side Type)When vertical space is limited, it is possible to install shelves side-by-side. Installing th

Strany 121

Installing the Basic Shelf and Expansion Shelf 1To install the Basic Shelf, attach the metal bracket (supplied with the Basic Shelf) to the base stand

Strany 122

2. Place the metal bracket on the base stands.Metal Bracket3. Attach the metal bracket to the base stands with 4 screws (B).Screw (B)92 Installation M

Strany 123

4. Make 4 holes for anchor plugs on the floor, using the measurements indicated here.510 mm(20-1/16 in)*FloorWall287 mm(11-5/16 in)95 mm(3-3/4 in)382

Strany 124

5. Install 4 anchor plugs in the holes on the floor.Then, fasten the base stands to the floor with 4 screws (A).Anchor PlugHammer30 mm(1-3/16 in)8 mm(

Strany 125

7. Lift the Basic Shelf, attach it to the metal bracket, and slide it backwards until it locks.FRONT12FRONT12TOPTOPMetal Bracket8. Secure the Basic Sh

Strany 126

Expansion Shelf 11. Fix the metal bracket to the Basic Shelf with 4 screws (B).TOPScrew (B)Metal Bracket2. Remove the 4 tabs on the top cover of Expan

Strany 127

3. Fasten the wall brackets loosely to Expansion Shelf 1 with 4 screws (D). (This makes it easy to adjust theposition of the shelves later.)Screw (D)W

Strany 128

5. Secure Expansion Shelf 1 to the metal bracket with 2 screws (B).Screw (B)Fixing to the Wall1. Install 4 anchor plugs in the wall, using the wall br

Strany 129

• When installing anchor plugs in the wall, be careful not to damage or dirty the shelves.Screw (A)WasherWallWall Bracket (Left) Wall Bracket (Right)A

Komentáře k této Příručce

Žádné komentáře